New chilled tower reduces annual electricity costs by approximately 54% compared to constant chiller operation.

For the production process, data center air conditioning, and cooling water for DLC servers: approximately 39% lighter than the current model, about 40% reduction in installation space, and using R32 as the refrigerant.

The new model is the "Chilled Tower CTS-A075M." For requests for the new catalog, please contact us. The catalog currently available features existing models. The new Chilled Tower integrates a chiller and a dry cooler, enabling hybrid operation suitable for outdoor temperature conditions throughout the four seasons and at any time of day. By setting the required chilled water temperature (10°C to 30°C), it automatically supplies stable chilled water with low power consumption. Additionally, the new Chilled Tower improves the COP with a new refrigeration cycle, providing a cooling capacity of 76 kW to 83 kW per unit. It can be connected with up to 25 units, accommodating over 1.5 MW of cooling. If you provide us with your usage conditions, we can help select the appropriate model and propose energy-saving calculations. Sustainability points of the Chilled Tower: Compared to continuous chiller operation, it reduces annual power consumption by approximately 54%, contributing to lower carbon emissions (continuous chiller operation refers to a scenario where the chiller operates year-round without the free cooling function of the Chilled Tower. Our calculation conditions are a supply water temperature of 20°C, ΔT = 5°C, cooling heat load of 56 kW, and weather conditions in the Tokyo area). On August 1, 2024, the piping equipment division of Protearial Co., Ltd. started anew as Kuwana Metal Industry Co., Ltd. under the capital of Okaya Steel Co., Ltd.

  • Air conditioning equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Adoption of refrigerant R32, energy-saving with free cooling, new type of chilled tower.

Production process, for cooling of data center air conditioning. Approximately 39% weight reduction compared to the current model, about 20% reduction in running costs, and approximately 40% reduction in installation space.

The chilled tower is a structure that integrates a chiller and a cooling tower, automatically operating in hybrid mode to match outdoor conditions in spring, summer, autumn, and winter, as well as day and night, providing stable supply of chilled water from 13°C to 35°C with low power consumption. For details on the new model specifications, please contact us. The new model supports up to 1.8 MW with a connection option. The catalog published is for the current model. Sustainability points of the chilled tower: Compared to a typical chiller, it reduces annual power consumption by approximately 54%, contributing to low carbon emissions (based on our calculations, this is without the free cooling function of the chilled tower compared to a typical chiller). On August 1, 2024, the piping equipment division of Protearial Co., Ltd. started anew as Kuwana Metal Industry Co., Ltd. under the capital of Okaya Steel Co., Ltd. For more details, please turn on the contact button and get in touch with us.